Reverse Osmosis Membrane Cleaning

Ultrapure & Industrial Services has been cleaning reverse osmosis and Ultra Filtration membranes for the power, pharmaceutical, hemo dialysis as well as several other industries for over 10 years. Membrane manufacturers such as Filmtec, Toray and Hydraunatics have determined that individual cleaning can improve and prolong life and production quality of membranes.

  • Call for membrane cleaning pricing on all manufactured 4" & 8" membranes.
  • Discounted annual contracts are available .
  • Standard services require approximately 20 working days from time of receipt of membranes. This time may vary depending upon the previous orders in process.

Reverse Osmosis Membrane Cleaning Procedure

  1. Prior to cleaning a membrane our technician inspects it, notes the condition, and installs it in the test/cleaning station and records pretest data.
  2. The membrane is cleaned with high pH caustic solution to remove biological fouling.
  3. The membrane is cleaned with low pH acid solution to remove metal ions.
  4. If necessary, the membrane is again cleaned with a high pH solution.
  5. The technician records post test data, then introduces a preservative and seals the membrane in a water tight container.
  6. All testing is performed to manufacturer's specifications

Contact Us

Total Service and Support For Water Treatment Systems

Ultrapure Headquarters

Dallas, Texas
Phone: 800-477-0309

Affiliated Service Centers

Boone, Iowa
Phone: 800-383-6382

Ft. Wayne, Indiana
Phone: 877-439-2626

Northfield, Minnesota
Phone: 800-283-8651

Austin, Texas
Phone: 800-765-4730